CLINICALLY PROVEN
Physician Controlled Beveled Needle Tip
UNIQUE EXTENDABLE AND
ROTATING BEVELED
NEEDLE TIP
Simplifies entry into proximal cap and enables intraluminal CTO crossing
INTUITIVE
EASY-TO-USE
HANDLE
Allows you to simultaneously “push and twist” the beveled tip to anchor and penetrate the lesion
HIGH CROSSING SUCCESS RATE
AND SHORT CROSSING TIME
Clinically proven efficiency in the Wing-It Clinical Trial 1
BRAID-REINFORCED
CATHETER SHAFT
Provides added strength for pushability through difficult lesions and kink resistance
HYDROPHILIC
COATING
Increases lubricity without compromising tactile feedback while enhancing trackability 2
TELESCOPING
COMPATIBILITY
Wingman 14/14c allow telescoping with Spex LP 35 and Spex 35 Shapeable Support Microcatheters for angulation, additional support, or coaxial alignment
References
1. Laird JR, Mathews SJ, Brodmann M, Soukas PA, Schmidt A, The Wing-It Trial Investigators. Performance of the Wingman catheter in peripheral artery chronic total occlusions: Short-term results from the international Wing-It trial. Catheter Cardiovasc Interv. 2021;97:310–316. doi:10.1002/ccd.29366
2. Wingman 14 is not hydrophilically coated.
©2024 Reflow Medical, Inc. All rights reserved. Reflow Medical, Wingman, and The Pulse of Medical Ingenuity are registered trademarks or trademarks of Reflow Medical, Inc. This device is restricted to use by or on the order of a physician. Refer to the Instructions for Use for a complete listing of the Indications, Contraindications, Warnings, Precautions, Complications, and Directions for Use.
Indications, Safety, & Warnings
CAUTION: This device is restricted to use by or on the order of a physician. Refer to the Instructions for Use for a complete listing of the Indications, Contraindications, Warnings, Precautions, Complications, and Directions for Use.
Indications for Use
The Wingman Crossing Catheters (14/14C/18/35) are intended to be used in conjunction with steerable guidewires to access discrete regions of the peripheral vasculature. It may be used to facilitate placement and exchange of guidewires and other interventional devices, including facilitation of the intraluminal placement of diagnostic/ interventional devices beyond peripheral stenotic lesions (including chronic total occlusions [CTOs]) and provide a conduit for delivery of saline solutions or diagnostic/therapeutic agents.
The Wingman 14C Crossing Catheter is intended to be used in conjunction with steerable guidewires to access discrete regions of the coronary vasculature. It may be used to facilitate placement and exchange of guidewires and other interventional devices and provide a conduit for delivery of saline solutions or diagnostic/therapeutic agents.
Contraindications
The Wingman 14, 18, & 35 Crossing Catheter is contraindicated for use in the coronary and cerebral vasculature. The Wingman 14C Crossing Catheter is contraindicated for use in the cerebral vasculature.
Warnings
Hydrophilic wires prone to excessive swelling (e.g. ZipWire) should not be used with the Wingman Crossing Catheter.
Single Use only. Do not reuse/resterilize. Reusing the device could result in compromised device performance, cross-infection and other safety related hazards.
Do not use if device is open or packaging is damaged
Never advance, withdraw or rotate an intravascular device against resistance until the cause is determined by fluoroscopy.
This device contains nickel and should not be used in patients with known allergies to nickel.
Precautions
Store in a cool, dry place. Protect from direct sunlight and high temperature.
Use only appropriately sized ancillary device, as shown in the Specifications below.
Maximum Infusion Pressure: 360 psi (2482 kpa)
Use the catheter prior to the “Use By” date specified on the package
The catheter should only be used by physicians qualified to perform percutaneous, vascular interventions.
Precautions to prevent or reduce clotting should be taken when any catheter is used in the vascular system. Use of systemic heparinization and heparinized saline solution should be considered.
Exercise care while handling the catheter during procedure to reduce the possibly of accidental damage, kinking or bending.
Manipulation of the catheter should only occur under fluoroscopy.
Complications
Vascular catheterization and/or vascular intervention may result in complications including but not limited to:
• Vessel dissection, perforation, rupture or total occlusion
• Infection
• Hematoma
• Unstable angina
• Embolism
• Hypo/hypertension
• Acute myocardial infarction
• Arrhythmia, including ventricular fibrillation
• Death
If the catheter is damaged, this product may cut into a blood vessel wall. Extreme caution needs to be taken when removing a damaged device. In the case of complications resulting from the removal of the entire system, stop immediately the procedure, and perform appropriate treatment at the discretion of the physician
©2024 Reflow Medical, Inc. All rights reserved. Reflow Medical, Wingman, and The Pulse of Medical Ingenuity are registered trademarks or trademarks of Reflow Medical, Inc. This device is restricted to use by or on the order of a physician. Refer to the Instructions for Use for a complete listing of the Indications, Contraindications, Warnings, Precautions, Complications, and Directions for Use.